DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-982S-SYN-PT (Speech Synthesis Port)
3
Hardware Error Log Entries and Test to Clear
Valu es
Notes:
a. An in-line failure of the on-board microprocessor/PSS handshake has
occurred. Refer to Test #168 for repair procedures.
Speech Synthesis Port Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0 Any Any Any test port PCSSpp sh r 1
1(a) 17672 None
18 0 busyout port PCSSpp WARNING OFF release port PCsspp
130(b) None WARNING ON test port PCSSpp sh
257 Speech Synthesis
PSS Handshake Test
(#168)
MAJOR ON test port PCSSpp sh r 2
513 17922 Speech Synthesis
Memory Test (#166)
MINOR ON test port PCSSpp sh r 2
769 17664 Speech Synthesis
DTMF Receiver
Inquiry Test (#164)
MINOR ON test port PCSSpp sh r 2
1025 17670 Speech Synthesis
SSD Inquiry Test
(#167)
MINOR ON test port PCSSpp sh r 2
1281 Speech Synthesis
DSP Tone Test (#165)
MINOR ON test port PCSSpp sh r 2
1537 Speech Synthesis
Memory Test (#166)
MINOR ON test port PCSSpp sh r 2
1793 Speech Synthesis
DTMF Receiver Test
(#163)
MINOR ON test port PCSSpp l r 2
2049(c) Conference Circuit
Test (#7)
MINOR ON test port PCSSpp l r 2
2305 NPE Crosstalk Test
(#6)
MINOR ON test port PCSSpp l r 2
3840(d) Any None