DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-349CLAN-BD (Control LAN Circuit Pack)
3
Notes:
a.
Error Type 1
: Circuit pack stopped functioning or is not physically
present.
1. Verify that the circuit pack is present.
2. If circuit pack is present, reset the circuit pack (
reset board
UUCSS
).
3. If the error persists, replace the circuit pack.
b.
Error Type 18
: The CLAN circuit pack busied out.
c.
Error Type 217
: applies to 10 circuit packs:
1. Remove the circuit pack(s) against which the error is logged.
d.
Error Type 257
: Transient communication problem between switch and
circuit pack; does not affect service and can be ignored.
1. Ignore this error, unless the Control Channel Loop Test (#52) fails.
2. If Test #52 fails, replace the circuit pack.
Repetitive failures of the Control Channel Loop Test indicate circuit pack
hardware failure.
e.
Error Type 513
: Circuit pack detected and reported hardware failure.
1. Reset the circuit pack (
reset board UUCSS).
3842 (t)
3844 (u) Any
3845 (v) Any
3846 (w) Any
3848 (x) Any
3849 (y) Any
3850-
3861 (z)
Any
3862 (aa) Any
Table 3-153. CLAN-BD Error Log Entries — Continued
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
Continued on next page