DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-873PE-BCHL (PRI Endpoint Port)
3
Error Log Entries and Test to Clear Values
Notes:
a. This error type indicates a disagreement between the switch and the
terminal adapter at the other end of the connection with regard to the
ISDN
call
state of the PRI Endpoint Port. This switch automatically tries to
recover by clearing the call (that is, the call is torn down). The
status
pri-endpoint <extension>
command can be used to determine the state
of the port.
When running the Short Test Sequence of tests, pay close attention to the
results of the Call State Audit Test (#257).
Table 3-376. PRI Endpoint Port Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0 Any Any Any test port PCSSpp sh r 1
1 (a) Any None test port PCSSpp sh r 1
15 (b) Any Audit and Update
Test (#36)
18 (c) 0 busyout pri-endpoint
<extension> busyout
port <PCSSpp>
WARNING OFF release pri-endpoint
<extension> release port
<PCSSpp>
129 (d) None WARNING OFF test port PCSSpp sh r 1
130 (e) None WARNING ON test port PCSSpp sh
257 (f) Any None test port PCSSpp sh r 1
513 (g) Any None WARNING OFF test port PCSSpp sh r 1
76 9 (f) Any None test port PCSSpp sh r 1
1281 (h) Any Conference Circuit
Test (#7)
MINOR ON test port PCSSpp l r 4
1537 (i) Any NPE Crosstalk Test
(#6)
MINOR ON test port PCSSpp l r 3
1793 (j) Any None test port PCSSpp sh r 1
3073 (k) Any Service State Audit
(#256)
test port PCSSpp sh r 2
3585 (l) Any None None
Continued on next page