Lucent Technologies 555-233-119 Home Theater Server User Manual


  Open as PDF
of 1872
 
DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance for csi systems
1-126ATM Tips
1
Ensure that the fields have the values indicated below.
2. If connections are being rejected, the
Last Cause Code
may give a clue
to why. The Cause Code (Table 1-16
below) indicating the error may be on
the PPN port even though the EPN port is the one misbehaving, and vice
versa.
Enter
show signaling cause
causecode
on the A500 console. Figure
1-54 shows the screen output for this command.
Figure 1-54. A500:show signaling cause 31
3. At the DEFINITY SAT type
display errors
and press
Enter.
Set the
Error List
to
errors
and
Category
to
PNC
on the input screen
(Figure 1-55
) and press Enter to display any Cause Codes (see Table 1-16
below) returned from the ATM network to a TN230X on the PPN (and to a
TN230X on an EPN). This is successful only if the links between the PPN
and the EPN remain up so that the message from the EPN is logged.
Refer to
‘‘ATM-BCH (ATM B-Channel Trunk)’’
for detailed information
regarding Cause Codes for this Maintenance Object.
Port
A1.2
(or the
port of
interest)
If this field is
not configured for UNI signaling
,
then the port was administered for no UNI signaling
(
admin link
command). Use the
show signaling
summary
command to verify that
Signaling
is
UNI3.1
.
Connect
Messages
Setup
Messages
Release
Messages
These counters should be non-zero if the A500 is
handling Q.93B protocol layer messages sent by the PPN
and EPN. They may not increase during troubleshooting
unless calls are being made, since the PPN initially sets
up control connections to the PPN and then sets up talk
path connections as needed.
A500:show signaling cause 31
Cause 31: Normal, unspecified