Lucent Technologies 555-233-119 Home Theater Server User Manual


  Open as PDF
of 1872
 
DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-64display errors
2
Form output
After completing the options screen, the system displays a 1- or 2-page
Hardware Error Report. To toggle between the pages and to exit the report, use
the keys described below:
For 513 and 715 terminals, use
F8
for NEXT PAGE and PREV PAGE commands
For all other terminals, use
F7
for NEXT PAGE and PREV PAGE commands
Use
Esc
for the
CANCEL
command
The screen below is an example of an Hardware Error Report -- Active Alarms,
without
the high-resolution qualifier in the command line.
Field descriptions
Extension
Enter the extension number
Trunk
Enter a group number or a group and member number:
Enter
only
the
group
number (01-99) to display
all
members in
the group. Example: 01/__
Enter
both
the
group
number
(01-99)
and
member
number
(01-99) to display a
specific
member in a group. Example:
01/99.
Port
Lists the location codes for the alarmed object, as follows:
Circuit packs locations display as:
cabinet-carrier-[slot]-[circuit]. Example: 01C702.
Port network locations display as: port network number-bus.
Example:
PN 01B
. PN 01 = Port Network (PN) number and A
or B = bus.
display errors Page 1 SPE A
HARDWARE ERROR REPORT - ACTIVE ALARMS
Port Mtce Alt Err Aux First Last Err Err Rt/ Al Ac
Name Name Type Data Occur Occur Cnt Rt Hr St
01C0702 ANL-LINE 311 257 01/31/09:20 01/31/20:26 255 256 255 a y
01C0701 ANL-LINE 1051 257 01/31/20:26 01/31/20:26 4 0 4 a y
01C0703 ANL-LINE 1053 257 01/31/20:26 01/31/20:26 4 0 4 a y
01A TDM-CLK 0 0 01/31/20:34 01/31/20:34 1 0 1 a n
01C1505 CO-TRK 078/001 3329 57408 01/31/20:26 01/31/20:27 5 300 5 a y
01C1505 CO-TRK 078/001 1537 01/31/20:26 01/31/20:28 5 150 5 a y
Command successfully completed