Maintenance Commands
2-65display errors
2
Maintenance
Name
Lists the logical name of the maintenance object with an error
logged against it.
Alt Name
Identifies the location of maintenance object, as follows:
Station = extension number
Trunk = Group number (78/__) or group and member
numbers (78/01)
Private CO Line = private CO line (P) and group number
(P/xxx)
Error Type
Lists the error number for the type of problem encountered for
this maintenance object. The technician must use this error
number in conjunction with the logical name information to
determine the exact nature of the error.
Aux Data
Lists additional information concerning the maintenance object
error condition. Like the error type, this data will be specific to the
maintenance object type. However, unlike the error code, only
the most recent value of the auxiliary data will be retained for
each error record.
First Occur
Displays the month, day, hour, and minute (and second if the
high-resolution command line option is used) that the error was
first recorded.
Seq Cnt
Sequence Count - This number indicates the order of errors
logged within a second for the time stamps associated with the
first occurrence and last occurrence of an error. This information
is displayed only if the
high-resolution
command line option is
entered. There may be gaps for the sequence numbers within a
given second since the last occurrence of an error may replace
an existing entry that had been assigned the missing sequence
number. Gaps may also appear in the numbers since sequence
counts are also used with software event information not shown in
the hardware error log.
Last Occur
Displays the month, day, hour, and minute (and second if the
high-resolution command line option is used) of the most recent
error. Note: if the system is unable to retrieve the time of day
when the error occurred, a ‘dummy’ date will be stamped in the
log and appears as:
00/00/01:07
.
Err Cnt
Error Count - The total number of times that the error type has
occurred for this maintenance object. If the number of errors
exceeds 3 digits, the system enters the number
256
, which
indicates that a larger number of errors occurred, but could not
be displayed correctly.