DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-955PR-MEM (RISC Memory)
3
Error Log Entries and Test to Clear Values
Notes:
a. This error (3) indicates that a software patch has been applied and either
the software patch is bad or was installed incorrectly.
1. Back out the software patch and run the
test memory a long
command to verify that the problem has been cleared.
b. The Aux Data indicate SIMM Failures.
c. Aux Data of 100 is an LMM Flash Checksum initialization failure.
d. There are Functional Memory Test errors against the Processor circuit
pack. This test is run only via a
reset system 4
command or a
reset
system 5
command.
System Technician-Demanded Tests: Descriptions
and Error Codes
Always investigate errors in the order in which they are presented in the table that
follows when you are inspecting errors in the system. By clearing error codes
associated with the
Read All Memory Test,
for example, you may also clear errors
generated from other tests in the testing sequence.
Table 3-414. Memory Error Log Entries
Error
Type Aux Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0 Any Any Any test memory a l r 1
1 Any Flash Memory
Checksum Test (#86)
MAJOR ON test memory a l r 5
3(a) Any Flash Memory
Checksum Test (#86)
MAJOR ON test memory a l r 5
1025 Any Memory Parity Error
Detection Test (#87)
MINOR ON test memory a r 3
1281 Any Memory Burst Read
Test (#908)
MAJOR ON test memory a l r 2
1793 Any (b)(c) Read All Memory (#85) MAJOR ON test memory a l r 1
2049(d) Any (b)(c) Memory Functional
Test (#332)
MAJOR ON test memory a l r 1