DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-474DID-TRK (DID Trunk)
3
Additional in-line testing is performed while a call is in progress. Thus, in-line
errors may occur during operation. See Error Log table for a description of these
errors. These errors may be reproduced by using the trunk (that is, placing a call)
and checking their occurrence in the Hardware Error Log.
Problems detected during signaling may be caused by faults off-board (in the
CO switch or connections) for which a Warning alarm is raised.
Before a maintenance test can be run on a port, the port must be idle. If an
incoming call seizes the port which is being tested by maintenance, the test is
aborted, and the incoming call proceeds.
For transmission and signaling standard specification, refer to Digital PBX
Standards document RS4648.
Hardware Error Log Entries and Test to Clear
Valu es
Table 3-200. DID Trunk Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
0 Any Any Any test port PCSSpp sh r 1
1 (a) Any None WRN OFF
1 (b) 57476 None WRN OFF
1 (c) 57477 None WRN OFF
1 (d) 57483 None WRN OFF
15 (e) Any Port Audit Update
(#36)
18 0 busyout trunk
<grp/mbr>
WRN OFF release trunk <grp/mbr>
130 (f) None WRN ON test trunk <grp>/<mbr>
257 (g) 57472 None WRN OFF
257 (h) 57473 None WRN OFF
257 (i) 57474 None WRN OFF
257 (j) 57475 None WRN OFF
513 (k) 57392 None MAJ/MIN/
WRN
2
OFF
510 (l) 57393 None
769 Any Port Diagnostic
(#35)
MAJ/MIN/
WRN
2
ON test port PCSSpp r 3
Continued on next page