DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-47display capacity
2
display capacity
This form describes how you have administered your system and provides a
"snapshot" status of the switch resources.
The screen below shows the output from the
display capacity
command.
NOTE:
The capacities listed may not coincide with your system. The figures that
follow are included to help explain the command and the field values, not to
provide capacity information.
Ack?
Headings 1 and 2 identify the first and second OSS telephone
numbers, respectively. The entries below indicate the
acknowledged alarm state:
y
(yes) = alarm has been acknowledged
n
(no) = alarm has
not
been acknowledged
c
(cleared) = alarm was first acknowledged, then resolved
and cleared
[Blank] = no attempt was made to report the alarm
NOTE:
If the user disables the alarm origination with the
change
system-parameters maintenance
command, then the
Ack?
field will be blank regardless of the true
acknowledged state of the alarm.
Date Alarmed
Month, day, hour, and minute of the alarm.
Date Resolved
Month, day, hour, and minute of the resolution (active alarms =
zeros)
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
display capacity
print
schedule
Report sent to printer
Command validated first, then a
scheduling form displays to
schedule execution of the
command. The command is then
placed in the command queue
and is executed at the specified
time. The information displayed is
sent to the system printer instead
of the screen.
1
1 Refer to the Report Scheduler and System Printer feature specification for more details.
init
inads
craft
cust
rcust
none none