Lucent Technologies 555-233-119 Home Theater Server User Manual


  Open as PDF
of 1872
 
DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-914PMS-LINK (Property Management System Link)
3
PMS-LINK (Property Management
System Link)
Property Management System (PMS) is a stand-alone computer system that a
hotel/motel-type and a hospital-type environment use for services such as
reservations, registration, messaging, housekeeping, night audit, billing, and
inventory. The PMS Link provides a communications channel between DEFINITY
Generic 1 or Generic 3iV2 and a customer-owned PMSs so that the PMS can
interrogate the system about the information related to the following features:
Message Waiting Notification
Controlled Restriction
Housekeeping Status
Check-in/Check-out
Room Change/Room Swap
Refer to
DEFINITY Enterprise Communications System Administrator’s Guide
for
details on the PMS feature. The PMS Link is administered to a data extension that
provides a standard EIA 232C interface to the PMS. A PMS can be connected
through a data module (PDM, MPDM, DTDM) and a port on the TN754 or
TN754B Digital Line circuit pack, or through an ADU and a port on the TN726
Digital Line circuit pack.
The PMS Link Maintenance strategy includes a set of tests for periodic diagnosis,
detection of errors during normal operation, actions for troubleshooting, and
raising alarms for serious problems. PMS Link Maintenance uses a "try-and-wait"
mechanism for maintaining the PMS Link. If a PMS Link is torn down due to an
error, PMS Link Maintenance attempts to bring up the link immediately. If the trial
of "Link Setup" fails, PMS Link Maintenance waits for five minutes before the next
retry. If the number of retries reaches the value of a threshold (12), a Minor alarm
is raised for service attention.
PMS Link Maintenance does not cover the maintenance of the elements
composing the PMS physical link (for example, the external PMS device, Data
Module (PDM/MPDM/DTDM), and Digital Line Port of TN754 or TN754B Digital
Line circuit pack, ADU and Data Line Port of TN726 Data Link circuit pack). If
PMS Link Maintenance cannot restore the PMS Link, then the maintenance tests
of these individual components of the PMS Link must be executed to diagnose
faults. If system technician-demanded
test pms-link
command fails, no alarm is
generated.
MO Name (in
Alarm Log)
Alarm
Level Initial Command to Run Full Name of MO
PMS-LINK MINOR test pms l PMS Link
PMS-LINK WARNING test pms PMS Link