Lucent Technologies 555-233-119 Home Theater Server User Manual


  Open as PDF
of 1872
 
DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-119ANN-PT (Announcement Port)
3
announcements
will not work, since the record port looks busy to the
circuit pack. Note that software does not have any way of knowing this and
attempts to use the ports.
If the circuit pack is locked into this state, the following symptoms are
observed:
1. When attempting to record an announcement, users hear the
proper record tone, but the announcement does not record (they
do not know it until the announcement is played back).
2. Performing a
test board long
when the circuit pack is in this state
yields the following abort codes:
Ports 1 and 9 abort Test #206 with code 1024
Ports 1 and 9 abort Test #205 with code 2000
Board level Tests #209 and #210 abort with code 1024
3. The
save/restore announcements
command times out with:
Error encountered, can’t complete request
The Announcement circuit pack lock-up can be cleared remotely by
performing a soft reset to the circuit pack:
busyout board PCSS
(this command drops all calls in progress on
the Announcement circuit pack)
reset circuit pack using the
reset board PCSS
command
release circuit pack using the
release board PCSS
command
140AY Channel Sanity Inquiry Test (#222)
The Angel keeps a sanity status bit for each of the 16 channels on the 140AY
device. This test queries the Angel to determine the status for a particular
channel. If a channel is insane, that implies that announcements cannot be
played back on that channel.
Table 3-46. TEST #222 140AY Channel Sanity Inquiry Test
Error
Code
Te s t
Result Description/ Recommendation
2000 ABORT Response to the test request was not received within the allowable time
period.
2100 ABORT Could not allocate the necessary system resources to run this test.
ABORT Internal system error.
1. Retry the command at 1-minute intervals a maximum of 5 times.