Lucent Technologies 555-233-119 Home Theater Server User Manual


  Open as PDF
of 1872
 
DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-17busyout tone-clock
2
Output
The following example is a display of the
busyout tdm
command.
Field descriptions
busyout tone-clock
The
busyout tone-clock
command places the specified tone/clock in a
maintenance busy state. No periodic or scheduled tests are performed on the
busied out object until it is released. When the object is maintenance busy it is
deactivated (no call processing activity may include the busied object). Warning
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
busyout tdm
pn
number
bus
pn number = TDM bus Port
Network number to be busied
out.
bus =
a
(default control bus) or
b
(default tone bus) specifies
desired half of TDM bus. Each
512 time slot TDM bus
configures as two duplicate 256
time slot buses. This division
allows duplication of control
channels and dedicated tone
time slots.
Examples:
busyout tdm 1a
init
inads
craft
none If a bus is busied
out, no calls are
torn down. and
no new calls are
set up.
Dedicated tone
time slots must
be moved to
another bus (the
other half of the
duplicated bus)
before a busyout
of a particular
bus is allowed.
Port
Port address and associated TDM number and bus (PNA or PNB)
Alt. Name
Not applicable
Maintenance Name
Type of busied out maintenance object:
TDM-BUS
Result
Test result: Pass, Abort, Fail
Error Code
Numeric code explaining why the release failed or aborted. Refer
to the detailed list of the codes by test number for each MO.
busyout tdm port-network 1 bus a SPE A
COMMAND RESULTS
Port Maintenance Name Alt. Name Result Error Code
PN 01A TDM-BUS PASS
Command successfully completed