DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-44display alarms
2
Options screen
When you enter the
display alarms
command, the system first displays the
options screen. Select the options you want to view on the report. The figure
below is an example of the options screen for Alarm Reports.
Field descriptions
ALARM TYPES
Enter
y
(yes) or
n
(no) in any of the 5 alarm type fields
Interval
Enter
one
of the codes below:
m
= last month
h
= last hour
d
= last day
w
= last week
a
= all (default)
From
Month/day/year (example: 01/01/97); if the
From
date is blank, the
report contains all the active alarms for the month
prior
to the current
date.
To
Month/day/year (example: 01/15/97); if the
To
date is not entered,
the report contains all the active alarms starting with the
From
date
to the current date.
Cabinet
Administered cabinet number (1-3)
Port Network
1-3
Board
Number:
Board address (
PCSS
); example: 01A20
Port
Port address (
PCSSpp
); example: 01A2031
display alarms Page 1 of 1
ALARM REPORTS
The following options control which alarms will be displayed.
ALARM TYPES
Active? y_ Resolved? n_
Major? y_ Minor? y_ Warning? y_
REPORT PERIOD
Interval: m_ From: __/__/__:__ To: __/__/__:__
EQUIPMENT TYPE ( Choose only one, if any, of the following )
Cabinet: ____
Port Network: __
Board Number: _______
Port: ________
Category: ________
Extension: _____
Trunk ( group/member ): ___/___