DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-23change synchronization
2
The following example shows the output for the
change synchronization
command. “3” was entered in the stratum field.
Field descriptions
Stratum:
Current synchronization stratum (3, 4)
Primary:
First choice system synchronization source (blank entry = no
synchronization); field valid only if stratum 4 synchronization is
specified.
Secondary:
Second choice system synchronization source (blank = no
synchronization); valid if stratum 4 synchronization selected
Location:
Circuit pack location of all administered DS1 circuit packs (port
network, carrier and board slot)
Name:
User-defined name for the DS1 circuit pack (blank = no user-defined
name assigned)
Slip:
If DS1 circuit pack has slip alarm,
y
; if not,
n
.
Port
Network:
Display-only field specifying the port network that supplies
synchronization through the tone clock circuit pack (valid for stratum 3
synchronization)
change synchronization Page 1 of 1
SYNCHRONIZATION PLAN
SYNCHRONIZATION SOURCE (circuit pack location)
Stratum: 4
Primary: _____ Secondary: _____
Location Name Slip Location Name Slip
NOTE: DS1 and BRI trunk sources will result in stratum 4, type II
synchronization
change synchronization Page 1 of 1
SYNCHRONIZATION PLAN
SYNCHRONIZATION SOURCE (DS1 circuit pack location)
Stratum: 3
Port Network: 1