DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-72AN-LN-PT (Analog Line Port)
3
AN-LN-PT (Analog Line
Port)
The TN793B/TN2793B Analog Line circuit pack (w/ Caller ID), and the TN797
Analog Trunk and Line circuit pack both support this Maintenance Object.
The TN793B/TN2793B Analog Line circuit pack (w/ Caller ID) provides 24 ports
for voice terminals and supports both on-premises and off-premises analog
voice terminals.
The TN797 Analog Trunk and Line circuit pack provides 8 ports, each of which
may be administered in any of several ways, as described in maintenance object
TR-LN-BD.
NOTE:
The TN793B/TN2793B analog line circuit pack supports analog data
modules. When assigned, analog data modules provide access to the
NetPkt (TN794 circuit pack) data ports. To activate an analog data module
you must assign the port location on the data form and connect a modem
to the port. The analog data module can be used for connection to a CDR
output, or other adjuncts as needed. These ports are tested the same as all
other analog ports on the circuit pack.
Ringing caused by maintenance testing
Test #48 may cause some terminal equipment to ring briefly during daily
maintenance. If this ringing disturbs the customer or the terminal equipment,
disable it in the
Tests
field of the
change station
extension
form. Be aware that
this action also disables Tests #6, 7, 161, and 35 on some software releases.
MO Name (in
Alarm Log) Alarm Level
Initial Command to
Run
1
1. UU is the universal cabinet number (1 for PPN, 2 -44 for EPNs). C is the carrier
designation (A, B, C, D, or E). SS is the number of the slot in which the circuit pack resides
(01 to 21). pp is the two digit port number (01, 02, ...).
Full Name of MO
AN-LN-PT MIN test port UUCSSpp l Analog Line Port
AN-LN-PT WRN test port UUCSSpp sh Analog Line Port