Lucent Technologies 555-233-119 Home Theater Server User Manual


  Open as PDF
of 1872
 
DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-1037TBRI-PT (TN2185 ISDN Trunk-Side BRI Port)
3
s. Error Type (3590): An activated BRI port receives a frame containing a
DLCI over a D-Channel for which it does not have a translation. This error
normally indicates an off-board problem related to a state mismatch
between the far-end and the switch. This error is logged only.
t. Error Type (3591): The port is generating too many uplinks and is taken out
of service.
u. Error Types (3841-3942): Table 3-457
contains the received ISDN cause
values for Errors 3841-3942 that are recorded in the hardware error logs.
Unless otherwise stated, the cause values are D-Channel events. The aux
data field shows which port caused the error.
Table 3-457. Cause Values for Error 3841-3942
Value Type of Problem Meaning
2 admin No route to specific transit network
3 admin No route to destination (or Germany bcap not imp)
6 admin Channel unacceptable
18 switch problems No user responding
38 switch problems Network failure
50 subscription Requested facility not subscribed
52 admin Outgoing calls barred
54 admin Incoming calls barred
62 subscription Service not authorized
63 admin/sub Service/option not available
65 admin/sub Bearer capability not implemented
66 admin/sub Channel type not implemented
69 admin/sub Requested facility not implemented
70 admin/sub Only restricted digital BC available
79 admin Service/option not implemented
88 admin Incompatible destination
102 switch problems Recovery on timer expired