DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-27change system-parameters maintenance
2
Alarm
Origination to
OSS Numbers
Indicates one of four options for alarm origination (
neither
):
both
= Major and Minor alarms result in an automatic call to both
administered OSS telephone numbers.
first-only
= Major and Minor alarms result in an automatic call to
the first administered OSS number.
neither
= alarm origination does not occur; reports are not sent to
either number.
second no-backup
= Major and Minor alarms result in an
automatic call to the first administered OSS telephone number. If
calling the first OSS telephone number fails four times, the switch
calls the second administered OSS telephone number until calling
the first OSS telephone number is successful.
If Alarm Origination is deactivated, Cleared Alarm Notification and
Restart Notification deactivate, even though they may still be activate
in the administration.
Cleared Alarm
Notification
The switch originates calls to the OSS and sends an alarm resolution
message once all previously-reported Major and Minor alarms are
resolved. Activate Alarm Origination to enable Cleared Alarm
Notification. (
no
)
Restart
Notification
Enables the switch to originate calls to the OSS and report any
system restarts caused by switch problems. Activate Alarm
Origination to enable Restart Notification.
Suspension
Threshold
Some problems cause alarms to be generated and resolved
repeatedly. To detect these problems, the switch suspends Cleared
Alarm Notification when it has reported the specified number of
Cleared Alarm notifications in a 24 hour period. A suspended
Cleared Alarm Notification reactivates with a successfully-completed
“logoff” command, a system reset, or when the threshold is
changed. This field is irrelevant if
Cleared Alarm Notification
or
Alarm Origination
are disabled. (1–15)
Test Remote
Access Port
Indicates if remote access testing on the SYSAM circuit pack is
active. This field should be set to
yes
when an INADS line is
connected to the switch and a maintenance contract is in effect to
maintain alarm origination capability.
If no equipment is connected to the remote access port, or if a trunk
for remote access and alarm origination is not provided, running tests
on the remote access port on the SYSAM results in test failures. This
causes unnecessary maintenance alarms and allows potentially
destructive tests to be run. To prevent this, set this field to
no
.