DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-341test hardware-group
2
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
test hardware-group
system
carrier
location
cabinet
location
board
location
print
schedul
e
System-wide test of all
hardware-groups
Carrier address: cabinet (1), carrier
(A)
1
Cabinet address (1)
2
Board location:
PCSS
3
Output sent to printer
Command validated and then a
scheduling form displays to
schedule execution of the command.
The command is then placed in the
command queue and is executed at
the specified time. The information
displayed by the command is sent to
the system printer instead of the
screen.
4
Examples:
test hardware-group system
test hardware-group system print
test hardware-group carrier 1a
test hardware-group carrier 1a
schedule
test hardware-group board 01c07
test hardware-group board 01c07
schedule
test hardware-group spe
test hardware-group spe print
test hardware-group spe schedule
1 The type of carrier may be port, or processor. In the case of a port carrier, all universal port and tone-clock boards (see
note 4) and its affiliated MOs residing in the specified carrier are tested. For a processor carrier, all SPE complex and
tone-clock boards and affiliated MOs are tested.
2 All PN and PNC related MOs plus cabinet specific MOs, including maintenance boards and environment (ring generator,
battery, power, emergency transfer, external alarms, fans, and temperature) are tested if they reside in the specified
cabinet location.
3 All MOs on the specified ’board location’ including ports are tested.
4 Refer to the Report Scheduler and System Printer feature specification for more details.
init
inads
Test
sequence
= short;
repeat = 1
See below