DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-675H323-SGRP (H.323 Signaling Group)
3
MedPro Status Test (#1392)
This test is non-destructive.
Voice calls over H.323 signaling groups are carried by media processor
resources. If there are no media processor resources in-service for the specified
signaling group, the H323 B Channels are placed into out-of-service near-end, so
that calls may flow to other trunk groups controlled by different signaling groups.
On the
ip-interfaces form
, the field
Inter-region IP connectivity
allowed?
may be set to
y
or
n
. If the field is set to
n
, only media processors in
the same region as the signaling group can carry calls.
This test determines if a media processor is in-service in the same region as the
C-LAN that carries this signaling group. If the field is set to
y
, any media
processor in the system can carry calls. This test determines if a media
processor is in-service in any region.
Table 3-282. TEST #1387 H.323 Signaling Group Ping Test
Error
Code
Te s t
Result Description/ Recommendation
1005 ABORT This signaling group has no administered far-end address. The test does
not apply to this configuration.
2800 ABORT A C-LAN ethernet port that corresponds to the near-end address of the
signaling group has not been administered.
ANY ABORT Refer to ETH-PT, Test #1281, C-LAN port PING test for a more detailed
description of the reasons for the abort.
ANY FAIL The far-end of the signaling group could not be reached.
1. Refer to ETH-PT, Test #1281, C-LAN port PING test for a more detailed
description of the reasons for the failure.
PASS The system can PING the administered far-end address of the H323
signaling group.
Continued on next page