Lucent Technologies 555-233-119 Home Theater Server User Manual


  Open as PDF
of 1872
 
DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-110list external-device alarm
2
Field descriptions
list external-device alarm
This command identifies any administered external devices, including the:
port identification
external device connected to the port
alarm level (major, minor, or warning) assigned to the external device
NOTE:
You must enable the External Device Alarm Admin? field (
y
) on the
System-Parameters Customer-Options form (
change system-parameters
customer-options
; init login required) before you can administer External
Device Alarm commands.
Output
The following example shows the output from the
list eda-external-device-alrm
command.
Screen 2-6. External Device Alarm Ports report
Maintenance
Name
The type of maintenance object (or group of maintenance objects) that
have been disabled.
All
is also valid.
Location
The physical location of the disabled maintenance object that has
been disabled. This field displays blanks if all maintenance objects
have been disabled (
disable all
) or all MOs of a specific type have
been disabled (
disable MO-all
).
Status
Whether the maintenance object or group of maintenance objects is
Enabled
or
Disabled
.
list eda-external-device-alrm Page 1 of 1 SPE A
EXTERNAL DEVICE ALARM PORTS
Port Alarm Alt Description Product
Type Name Identifier
01c1201 minor UPSI DC battery discharged 7000000001
01c1202 major Audix1 Main Audix main equipment 8123456790
01major minor UPSI DC rectifier alarm 7000000001
01minor minor UPSI DC overvoltage alarm 7000000001
03a2101 warning CC temp Computer Center Temperature
03a2102 major CMS2 Call management adjunct 6222222222
03major major CMS1 Call management adjunct 6111111111
03minor minor Audix2 Audix 2 remote equipment 8123456791