DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-37ANL-24-L (24-Port Analog Line)
3
impedance. Call the terminal equipment and verify that the terminal
rings. If the terminal does not ring, then replace it. Otherwise, issue
the
test port PCSSpp
command, and follow the procedure for
Test #48.
40977 indicates that no terminal equipment was connected when
ringing was attempted. Run the short test via the
test port PCSSpp
command, and follow the procedure for the results of Test #48.
b. This is a software audit error that does not indicate any hardware
malfunction. Run Short Test Sequence and investigate associated errors.
c. This error type indicates that the circuit pack has been removed or has
been insane for more than 11-minutes. To clear the error, reseat or replace
the circuit pack.
d. This is an in-line error and can only be resolved over time. This error
indicates that ringing voltage is absent. If only 1 analog circuit pack in the
system has this problem, then replace the circuit pack. If only analog
circuit packs on a particular carrier have this error, then the ringing
generator may not be connected to this carrier. If analog circuit packs on
many carriers have this error, then it is probably a problem with the ringing
generator.
e. Test #48 may cause some terminal equipment to ring briefly during daily
maintenance. If this disturbs the customer or the terminal equipment,
disable it by setting the
Tests
field on the
change station
extension form
to
n
. On some software releases, this will also disable Tests #6, 7, 161,
and 35.
System Technician-Demanded Tests: Descriptions
and Error Codes
Always investigate tests in the order presented in the table below when
inspecting errors in the system. By clearing error codes associated with the
Battery Feed Test,
for example, you may also clear errors generated from other
tests in the testing sequence.