Lucent Technologies 555-233-119 Home Theater Server User Manual


  Open as PDF
of 1872
 
DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-491DIG-IP-STN (Digital IP Station)
3
Notes:
a.
Error Type 1
: this error reports the registration status of the endpoint. If
call processing SW claims the endpoint is registered and receives
keep-alive handshakes from the endpoint, the test passes. If keep-alive
handshaking has failed, the test fails. If the user has intentionally
un-registered from DEFINITY, the station is now basically an AWOH station
and is no longer being maintained; no tests will run for this station.
b.
Error Type 257
: this error tracks failures of the signaling path PING test.
The test attempts to send a PING packet to the endpointIP address, as
reported during registration. The PING packet originates with the C-LAN
board through which the endpoint is registered. If the PING response
packet is received, the test passes. If the PING response packet times
out, the test fails.
c. This is a refresh of the lamp states for all lamps on the Virtual DCP station.
The update always passes, if it runs successfully. It may abort, but it will
never fail. This update is the same update used for existing DCP stations.
It is test number 16.
d. This is a refresh of the ringer state on the Virtual DCP station and a query
of the virtual station’s switch-hook state. The audit always passes, if it runs
successfully. It may abort, but it will never fail. This runs a subset of the
complete audit update that runs for standard DCP sets.
e.
Error Type 2817
: this error tracks failures of the port hyperactivity counter.
If a port generates more than 50 uplink CCMS messages within 10
seconds, the port is taken out-of-service for 30 seconds. Even though the
Virtual phone actually signals over a TCP/IP link, DCP CCMS messages
received over the TCP link are counted as regular CCMS uplinks and can
cause the station to marked as hyperactive.
2817
(e)
Station Hyperactivity
Table 3-205. DIG-IP-STN Digital IP Station Error Log Entries — Continued
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
Continued on next page