Maintenance Objects
3-543DIOD-TRK (DIOD Trunk)
3
Port Audit Update Test (#36)
This test sends updates of the CO port translation for all ports on the circuit pack
which have been translated. The update is non-disruptive and guards against
possible corruption of translation data contained on the circuit pack. No
response message is expected from the circuit pack once it receives translation
updates. The port translation data includes: ground or loop start trunk, tone or
rotary dialing trunk, rotary dialing inter-digit timing, network balance R/RC, and
disconnect timing.
7 FAIL 1. Check for errors on TONE-BD or TONE-PT. If there are errors, take the
appropriate actions.
2. If the Reflective Loop Around Test fails for all ports on a circuit pack, a
-5 volt power problem is indicated.
3. Rerun the test.
4. If the test fails again, replace the circuit pack.
PASS CO Trunk Loop Around and Conference Test is successful. User-reported
troubles on this port should be investigated by using other port tests and
by examining trunk or external wiring.
Table 3-230. TEST #33 Loop Around and Conference Circuit Test — Continued
Error
Code
Te s t
Result Description/ Recommendation
Continued on next page