Maintenance Commands
2-188release pms-link
2
release pms-link
This command deactivates MOs that are associated with a property
management system link. These links provide asynchronous data connections
from switches to peripherals; they are composed of a:
■ Far end data module
■ Simulated data channel on a NETCON board
■ Manager that initiates and maintains the link
■ Controller/protocol that services the link
Feature Interactions
Specific component maintenance performed on a link sometimes conflicts with
link maintenance, itself (busied out objects create link setup failure). Frequent
link re-setup attempts may delay faulty component recovery. For best results,
technicians should use busyout to disable attempted link re-setup.
Output
The following example shows the output from the
release pms-link
command.
Field descriptions
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
release
pms-link
init
inads
craft
none see below
Port
This field is left blank.
Maintenance Name
PMS-LINK
Alt. Name
Not applicable.
release pms-link
COMMAND RESULTS
Port Maintenance Name Alt. Name Result Error Code
PMS-LINK PASS
Command Successfully Completed