DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-1128TONE-BD (Tone-Clock Circuit Pack)
3
TONE-BD (Tone-Clock Circuit Pack)
The Tone-Clock circuit pack functionality is provided by two independent objects
in the same circuit pack. The tone generator provides all the tones needed by the
system and the clock generates the system clocks for the Time Division Multiplex
(TDM) Bus and aids in monitoring and selecting internal synchronization
references.
When resolving errors/alarms on the Tone-Clock circuit pack, the following
should be used also:
TONE-PT (Tone Generator) Maintenance documentation.
TDM-CLK (TDM Bus Clock) Maintenance documentation.
SYNC (Synchronization) Maintenance documentation.
The TN2182 is a combined Tone-Clock/Detector circuit pack that contains 8
ports used for all-purpose tone detection. These ports are called Enhanced Tone
Receiver ports (ETR-PT) and are described in the documentation for ETR-PT.
Tone-Clock Circuit Packs
CMC systems have one Tone-Clock circuit pack in each port network. This is in
the A carrier. This Tone-Clock circuit pack generates clocks and provides system
tones for all carriers of the port network it resides on.
Italian Tone Settings (New ISPT Value)
The TN2182 allows International changes, but allows the customization of up to
24 system tones in order to meet specific country needs. These changes are
made via the
change system-parameters country-options
form.
MO Name (in
Alarm Log)
Alarm
Level Initial Command to Run
1
1. P is the port network number (1). C is the carrier designation (A, B, or C).
Full Name of MO
TONE-BD MAJOR test tone-clock PC Tone-Clock Circuit Pack
TONE-BD MINOR test tone-clock PC Tone-Clock Circuit Pack
TONE-BD WARNING release tone-clock PC Tone-Clock Circuit Pack
Tone Default Old ISPT Value
Dial Continuous Cadenced
Confirmation Cadenced Continuous