Maintenance Objects
3-1110TIE-TRK (Tie Trunk)
3
Notes:
a. Digit time-out. This occurs when the far-end PBX begins transmitting digits
too late (10 seconds) after receiving the signal indicating ready to receive
digits (if any). This can occur on an incoming immediate, wink, or delay
dial line. Check the far-end PBX to ensure a translation match at both
ends.
b. Rotary dial before wink. This occurs when the far-end PBX starts dialing
before the PBX sends the wink on a wink-start or (for non-TN439 circuit
packs) on a delay-dial line. Check the far-end PBX to ensure a translation
match at both ends.
c. Rotary dial too early. This occurs when the far-end PBX starts dialing too
soon (about 50ms) after seizure on a wink start or (for non-TN439 circuit
packs) on a delay-dial line. Check the far-end PBX to ensure a translation
match at both ends.
d. On hook before wink. This occurs when the far end goes on hook before a
wink. Check the far-end PBX to ensure a translation match at both ends.
e. On an outgoing wink-start or delay-dial trunk, the wink time was too short
(less than 80ms) for a valid signal. Check the far-end PBX to ensure a
translation match at both ends.
2305 (m) 50944 None; Seizure (#73)
3
; Tie
Trunk Dial (#747)
2305 (m) 57424 Tie Trunk Dial (#747)
2561
3
0
3
None
3
v WARNING
3
OFF
3
2817
3
0
3
None
3
MINOR
3
OFF
3
3073
3
0
3
None
3
3840 (n) 8000 Analog Transmission
(#844-848)
OFF
3841 (n) Analog Transmission
(#844-848)
MINOR OFF test analog testcall
PCSS pp r 2
1. Minor alarms on this MO may be downgraded to Warning alarms based on the values used in the set
options command. If the MINOR alarm is not downgraded by the set options values, the MINOR alarm is
upgraded to a MAJOR alarm if 75 percent of the trunks in this trunk group are alarmed.
2. Non-TN497 circuit packs only.
3. TN497 circuit packs only.
Table 3-490. TIE Trunk Error Log Entries — Continued
Error
Type Aux Data Associated Test Alarm Level
On/Off
Board Test to Clear Value
Continued on next page