Lucent Technologies 555-233-119 Home Theater Server User Manual


  Open as PDF
of 1872
 
DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-123list measurements ds-1
2
Field descriptions (list measurements
ds1-summary)
Counted
Since:
The start time and date when the associated measurement counters
were cleared or the DS1 circuit pack was administered.
Number of
Seconds
Elapsed Into
Current
15-min
Interval:
The number of seconds from the beginning of the current 15-minute
interval (0 - 900).
Total of
Valid 15-min
Intervals in
Past 24-hr
Period:
The total number of 15-minute intervals in the past 24-hour period that
contain valid data (0 - 96).
Category
The four categories correspond to four measurement error counters:
Errored Seconds
: the value of the errored seconds counter for
the specified 15-minute interval (0 - 900 or N/A if data for the
15-minute interval is invalid).
Bursty Err Secs
: the value of the bursty errored seconds
counter for the specified 15-minute interval (0 - 900 or N/A if data
for the 15-minute interval is invalid).
Severely Err Secs
: the value of the severely errored seconds
counter for the specified 15-minute interval(0 - 900 or N/A if data
for the 15-minute interval is invalid).
Failed Seconds
: the value of the failed seconds counter for the
specified 15-minute interval (0 - 900 or N/A if data for the
15-minute interval is invalid).
Worst_15-Min_
Interval
The date(Date), end time(Time), and error count (Count; from 0 to 900
in increments of four) of the 15-minute interval in the previous 24-hour
period that contains the maximum value for each of the four error
categories.
Total of
24-Hour Count
The sum of all valid 15-minute counts for the previous 24-hour period
for each of the four error categories (0 - 65535).
Current
15-Minute
Interval
The error count for the current (incomplete) 15-minute interval for each
of the four error categories (0 - 900 or N/A if data for the 15-minute
interval is invalid).