DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-945PR-MAINT (Maintenance Processor)
3
MTP Outpulse Relay Test (#102)
This test is a nondestructive test. The test validates the correct operation of the
remote access CO trunk used by INADS. The MTP first goes off-hook, then
on-hook on this trunk. If the loop current is detected, the test passes. This test is
not allowed if the remote access line is in use.
PASS The Maintenance/Tape Processor was reset, and it passed initialization
correctly. The other MTP tests should be examined to verify that the MTP is
functioning correctly.
1. Enter test processor a/b and verify that the MTP is functioning
correctly.
Table 3-408. TEST #102 MTP Outpulse Relay Test
Error
Code
Te s t
Result Description/ Recommendation
1029
2014
2015
2016
2017
2018
2020
2022
2024
2025
2051
ABORT Refer to STBY-SPE Maintenance documentation for a description of these
error codes.
1018 ABORT The test has been disabled via administration.
1. To enable the test, issue the change system-parameters maintenance
command, and set the test remote access port field to "y." (If you have
an INADS line, set the field to "y." If you are testing the Standby
PR-MAINT, a refresh spe-standby command must be successfully
executed before you proceed to Step 2.
2. Rerun the test.
Continued on next page
Table 3-407. TEST #101 MTP Reset Test — Continued
Error
Code
Te s t
Result Description/ Recommendation
Continued on next page