DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-820MET-LINE (MET Line)
3
Port Diagnostic Test (#35)
This test checks a port’s battery feed circuitry. The battery feed circuitry is tested
for proper battery voltage by testing the switchhook state. In response to the test
message, the on-board firmware terminates the line and checks for switch-hook
presence. The termination is then removed, and a check is made for no
switch-hook presence. The MET set must be on-hook for the test to execute.
Table 3-355. TEST #35 Port Diagnostic Test
Error
Code
Tes t
Result Description/ Recommendation
ABORT Internal system error.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1000 ABORT System resources required to run this test are not available. The port
may be busy with a valid call. Use the display port PCSSpp command
to determine the station extension, attendant number, or trunk
group/member number of the port. Use the status station, status
attendant, or status trunk command to determine the service state of
the port. If the service state indicates that the port is in use, then the
port is unavailable for certain tests. You must wait until the port is idle
before retesting. Attendants are always in use (off-hook) if the handset
is plugged in and the port is not busied out.
1. If the port status is idle, then retry the command at 1-minute
intervals a maximum of 5 times.
1004 ABORT The port was seized by a valid call during the test. The test has been
aborted. Use the display port PCSSpp command to determine the
station extension of the port. Use the status station command to
determine the service state of the port. If the service state indicates that
the port is in use, then the port is unavailable for certain tests. You must
wait until the port is idle before retesting.
NOTE:
The battery feed circuitry is tested for proper battery voltage by
testing the switchhook state. In response to the test message,
the on-board firmware terminates the line and checks for
switch-hook presence. The termination is then removed, and a
check is made for no switch-hook presence. The MET set must
be on-hook for the test to execute.
1. If the port status is idle, then retry the command at 1-minute
intervals a maximum of 5 times.
1018 ABORT Test disabled via software patch.