DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-12busyout port
2
Output
The following example is a display of the
busyout pms-link
command.
Field descriptions
busyout port
This command places the specified port on a circuit pack in a maintenance busy
state. No periodic or scheduled tests are performed on the busied out port until it
is released. When the object is maintenance busy, it is deactivated (no call
processing activity may include the busied object). Warning alarms (error type
18) are generated on each busied out maintenance object, so that INADS can
determine the state of the objects. The command,
release port,
reactivates the
administered port on a circuit pack at a specified location.
Port
Always blank
Maintenance Name
Name of maintenance object:
PMS-LINK
Alt. Name
Not applicable.
Result
Test result: Pass, Abort, Fail
Error Code
Numeric code explaining why the release failed or aborted. Refer
to the detailed list of the codes by test number for each MO.
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
busyout port
location
Port address:
PCSS
marked port:
PPSSpp
Examples:
busyout port 01c1101
busyout port 02c1501
init
inads
craft
none see below
busyout pms-link SPE A
COMMAND RESULTS
Port Maintenance Name Alt. Name Result Error Code
PMS-LINK PASS
Command Successfully Completed