DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-366CLSFY-PT (Call Classifier Port)
3
CLSFY-PT (Call Classifier Port)
The TN744D Call Classifier (CLSFY-BD) circuit pack is a service circuit pack that
enables usage of the Outbound Call Management (OCM) and the Inbound Call
Management (ICM) features. The TN744D also enables usage of R2-MFC
signaling for incoming and outgoing feature operation. There are eight ports
(CLSFY-PTs) on the Call Classifier circuit pack. Each port can handle call
classification, touch-tone reception, or MFC tone generation and detection or
touch-tone reception.
The CLSFY-PT maintenance feature defines a set of tests to ensure that the Call
Classifier circuit pack ports are capable of detecting tones for call classification
and detecting and generating necessary tones for correct MFC feature
operation.
NOTE:
A TN744D Call Classifier/Tone Detector circuit pack may be required in
systems with heavy traffic. This circuit pack can be installed into any port,
although slot 1 of Cabinet B is preferred.
MO Name (in
Alarm Log)
Alarm
Level Initial Command to Run
1
1. Where P is the port network number (1 for PPN); C is the carrier designation (A, B, or C); SS is the
address of the slot in the carrier where the circuit pack is located (01, 02, ..., and so forth); and pp
is the 2-digit port number (01, 02, ..., and so forth).
Full Name of MO
CLSFY-PT(a) MAJOR test port PCSSpp sh Call Classifier Port Maintenance
CLSFY-PT MINOR test port PCSSpp sh Call Classifier Port Maintenance
CLSFY-PT WARNING release port PCSSpp Call Classifier Port Maintenance