DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-1014SYS-LINK (System Links)
3
down. The other path, the faulted path is present if the link has ever gone down
or never come up. If the link came up and went down, then the faulted path is
marked "Present". If the link never came up, the faulted path is marked "Default".
Either case, it represents the path on which the link was attempted or established
unsuccessfully.
Test command for the system links,
test sys-link PCSSpp
can be specified with
current or faulted as an optional argument if the user wishes to test all the
components in the specified path. The tests executed will be the same if the user
were to test each component manually. In the event that the user does not
specify any path, then only the tests specified for the system links are executed.
System Link Status (#985)
This non-destructive test queries the switch for the status of the system link and
verifies that all switch components have the same view of the link state.
Order of Investigation
Short Test
Sequence
Long Test
Sequence D/ND
1
1. D = Destructive, ND = Non-destructive
System Link Status (#985) X X N
Table 3-449. TEST #985 System Link Status
Error
Code
Tes t
Result Description/ Recommendation
1007 ABORT Could not locate the system link associated with this location
1. Retry the command at 1-minute intervals for a maximum of 5 times.
2500 ABORT Internal system error
1. Retry the command at 1-minute intervals for a maximum of 5 times.
6 FAIL The system link is down.
1. Follow the procedure for error type 13.
PASS The system link is up.