Lucent Technologies 555-233-119 Home Theater Server User Manual


  Open as PDF
of 1872
 
DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-1197UDS1-BD (UDS1 Interface Circuit Pack)
3
1302 FAIL Attempting to use the 120A1 CSU Module with a TN464F circuit pack that is
configured for 32-channel (2.048 Mbps) operation. The CSU Module only works
with a DS1 board configured for 24-channel (1.544 Mbps) operation in the
United States of America.
1. If the 120A1 CSU Module is to be used, physically remove the TN464F
circuit pack and reconfigure for 24-channel (1.544 Mbps) operation.
2. Reinsert the circuit pack and run the test again.
1303 FAIL The DS1 circuit pack Suffix is incorrect for CSU Module/T1 Sync Splitter or E1
Sync Splitter administration.
The DS1 circuit pack Suffix is incorrect for CSU Module/T1 Sync Splitter
administration. The
Near-End CSU Type
field on the
add ds1
form has been
administered as
integrated but the DS1 circuit pack is not a TN464F or
later suffix UDS1 board.
1. If the CSU Module/T1 Sync Splitter is to be used, and the
Near-End CSU
Ty p e
field is set to integrated to allow for CSU Module/T1 Sync Splitter
administration, remove the circuit pack and replace it with a TN464F or later
suffix board. Otherwise use the
change ds1
command to change the
Near-End CSU Type
field to
other
.
The DS1 circuit pack Suffix is incorrect for E1 Sync Splitter administration. The
E1 Sync-Splitter?
field on the
add ds1
form has been administered as
y
but the
DS1 circuit pack is not a TN464F or later suffix UDS1 board.
1. If the E1 Sync Splitter is to be used, and the
E1 Sync-Splitter?
field is set to
y
to allow for E1SS administration, remove the circuit pack and replace it
with a TN464F or later suffix board. Otherwise use the
change ds1
command to change the
E1 Sync-Splitter?
field to
n
.
1310 FAIL The DS1 Board Loopback (BLB) demand test (#1209) failed.
1. Repeat the test using the
test ds1-loop UUCSS ds1/csu-loopback-tests
command.
2. If the BLB test continues to fail, then replace the TN464F circuit pack.
3. Run this test again.
Table 3-519. TEST #138 Loss of Signal Alarm Inquiry Test — Continued
Error
Code
Te s t
Result Description/ Recommendation
Continued on next page