DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-361test packet-interface
2
Feature Interactions
If the packet-interface circuit pack is in the “out-of-service” or “uninstalled”
states, no demand, scheduled, periodic, or error tests can run. See also ‘‘reset
packet-interface’’ and
‘‘status packet-interface’’
.
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
test
pkt-interface
location
short
long
repeat
number
clear
schedule
The packet interface to be tested:
nn
(cabinet 1-3 + carrier letter)
Option for a brief series of
nondestructive diagnostic tests.
Option for a longer, more
comprehensive series of both
destructive and nondestructive
diagnostic tests.
How many times each test in the
sequence is repeated (1-100)
This option causes the test sequence
(short or long) to repeat until the alarm
(if any) is cleared or a single test in the
sequence fails.
1
Command is validated and then a
scheduling form displays to schedule
execution of the command. The
command is then placed in the
command queue and is executed at
the specified time. The information
displayed by the command is sent to
the system printer instead of the
screen.
2
Examples:
test packet-interface 01a
1 If no alarms are registered against the maintenance object then the test sequence is run only once. The
long clear
option forces a clear of all alarms if no errors are encountered during testing. The
short clear
option only clears
alarms pertinent to tests in the short sequence.
2 Refer to the Report Scheduler and System Printer feature specification for more details.
init
inads
craft
test
sequence
= short;
repeat
number =
1
see below