DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-331test data-module
2
Output
The following example shows the output from the
test customer-alarm 02a
command.
Field Definitions
test data-module
This command performs hardware diagnostic tests on a data module or data
channel. Test results are determined by the interface to the digital switch-data
line port, digital line port, or network control data channel.
Port
The port address (cabinet-carrier-slot)
Maintenance
Name
The maintenance name (always CUST-ALM)
Alt. Name
Not applicable
Test No.
The test number (always 115)
Result
Test result: Pass, Abort, or Fail
Error Code
Numeric code explaining why the release failed or aborted. Refer
to the detailed list of the codes by test number for each MO.
test customer-alarm 02A
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
02A CUST-ALM 115 PASS
Command Successfully Completed