DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-298BRI-SET, ASAI-ADJ, BRI-DAT
3
m. Certain ISDN-BRI cause codes are logged by switch software. The cause
code can be determined from the following formula:
If the error type is greater than 3968, then the ISDN-BRI cause code is
equal to the error type minus 3968. This code was sent to the endpoint by
the switch.
63 Service or Option
Not Available
Requested ASAI capability or resource is not
available on the switch or adjunct. More than one
adjunct may be contending for the same switch
resources. Potential administration mismatch
between the resource domains administered on
the switch and those administered on the adjunct.
1. Verify that no overlapping administration of
switch resources (for example, requesting
notifications on a single domain by multiple
adjuncts or multiple adjuncts attempting to
control a single call) exists across all adjuncts
connected to the switch. If overlaps exist, then
readminister the adjuncts to guarantee that
each adjunct is associated with a unique set of
switch resources.
Service or Option
Not Implemented
79 Service or Option
Not Implemented
Requested service or option (or combination of
selected options) is not supported (implemented)
in switch or the adjunct.
1. Consult switch and adjunct documentation to
determine ASAI service and options supported
by both switch and adjunct. Readministration
of the switch-administered capabilities (see
Customer Optional Feature Form) or those of
the adjunct may be necessary to correct the
problem.
Switch Error
Conditions
87 Internal Switch
Audit
There is an inconsistency in switch data records.
1. There is no action needed since the switch has
corrected the data inconsistency.
2. If a number of these errors continue to occur,
then escalate to next tier.
Table 3-130. ASAI Cause Values — Continued
Code Explanation Recommendation
Continued on next page