DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-686HYB-LINE (Hybrid Line)
3
Notes:
a. Indicates a defective data link. An off-board problem was detected by port
circuit. Verify that the Hybrid set is connected and that the EPF test
passes. If data transmission problems are experienced, check for
defective wiring or a defective voice terminal, or move terminal closer to
the switch (in terms of feet of wire from the jack to the switch). If the
problem still exists, replace the circuit pack. Once the problem has been
resolved, the alarm is retired after a predetermined period of time.
b. This is a software audit error that does not indicate any hardware
malfunction. Run Short Test Sequence and investigate associated errors
(if any).
c. This error type is logged when the port in question is busied out by
maintenance personnel. Make sure port is released from busyout via the
release port PCSSpp
command.
d. This error type indicates that the circuit pack has been removed or has
been insane for more than 11 minutes. To clear the error, reinsert or
replace the circuit pack.
513 (f) 40965 Hybrid Line Audits
Test (#61)
WARNING OFF test port PCSSpp sh r 4
769 (g) Remote Dig Loop
Around Test (#59)
WARNING OFF test port PCSSpp sh r 3
1025 Hybrid & Conf.
Circuits Test (#57)
MIN/WRN
2
ON test port PCSSpp l r 3
1281 (h) Local Digital Loop
Around Test (#58)
WARNING ON test port PCSSpp l r 3
1537 (i) 40968 None WARNING OFF
1793 TDMNPE Crosstalk
Test (#6)
MIN/WRN
2
ON test port PCSSpp l r 3
2049 (j) 32770 None
2049 (k) 40967 None
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate
test description and follow the recommended procedures.
2. Major or Minor alarms on this MO may be downgraded to Warning alarms based on the values used in
the set options command.
Table 3-288. Hybrid Line Error Log Entries — Continued
Error
Typ e
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
Continued on next page