Lucent Technologies 555-233-119 Home Theater Server User Manual


  Open as PDF
of 1872
 
DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-806MEDPROPT (TN802 MED PRO DSP PORT)
3
MEDPROPT (TN802 MED PRO DSP
PORT)
The MEDPROPT maintenance object monitors the health of the MEDPRO digital
signal processors (DSPs).
The TN802B MAPD (Multi-Application Platform for DEFINITY) Media Processor
circuit pack provides the audio bearer channels for H.323 voice over IP calls.
One TN802B circuit pack has one MEDPROPT media processing resource.
Based on system administration of audio codecs, a MEDPROPT can handle
either 31 or 22 simultaneous channels of H.323 audio processing. If the
ip-parameters
form specifies only G.711 Mulaw or G.711 Alaw as the audio
codecs, the MEDPROPT can service 31 channels. If any other codec type
(G.723-5.3K, G.723-6.3K, or G.729) is administered, the MEDPROPT can only
service 22 channels.
The MEDPROPT is physically made up of 11 individual DSPs, but is treated
logically as one port. If individual DSPs on the TN802B MAPD fail, the
MEDPROPT remains in-service at lower capacity.
The MEDPROPT is a shared service circuit. It is shared between H.323 trunk
channels and H.323 stations. An idle channel is allocated to an H.323
trunk/station on a call-by-call basis.
Error Log Entries and Test to Clear Values
MO Name (in
Alarm Log) Alarm Level
Initial Command to
Run Full Name of MO
MEDPROPT MINOR/WARNING test port UUCSS or
PCSS [short/long]
[repeat#] | [clear]
TN802 MED PRO DSP PT
Table 3-349. MEDPROPT Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
0 Any Any Any test board UUCCSS
1(a) DSP Capacity Test
(#1382)
ON test board UUCCSS l r5
258(b) DSP Capacity Test
(#1382)
WARNING ON test board UUCCSS l r5
Continued on next page