Lucent Technologies 555-233-119 Home Theater Server User Manual


  Open as PDF
of 1872
 
DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-209set options
2
If technicians set the option “warning” or “report,” port circuit pack LEDs and
LEDs on the Maintenance circuit pack are affected the same as warning alarms.
Default parameters are:
The system downgrades all station, trunk (except on-board trunk alarms),
and Minor DS1-BD alarms to warning alarms.
On-board Major and Minor trunk alarms, and the Memory Card Capacity
alarm continue to raise alarms and report to INADS.
Station MOs Affected By This Command
NOTE:
Although alarms on some MOs appear as warnings, they should be
investigated with user-reported problems.
Analog Lines (ANL-LINE, ANL-NE-L, ANL-16-L)
Digital Lines (DIG-LINE)
Hybrid Lines (HYB-LINE)
MET Lines (MET-LINE)
ISDN-BRI Lines (BRI-PORT, BRI-SET)
If more than 75% of the members of the trunk group alarm, minor arms escalate
to major alarms. If the trunk category option is set to “warning,” “minor,” “report,”
or “no,” this no longer happens. Maintenance reactivates individual trunk
members according to Major and Minor alarm criteria.
Trunk MOs Affected By This Command
NOTE:
Although alarms on these MOs may appear as warnings, the alarms should
be investigated with user-reported problems.
Auxiliary Trunks (AUX-TRK)
Central Office Trunks (CO-TRK)
Direct Inward Dialing Trunks (DID-TRK)
Direct Inward and Outward Dial Trunks (DIOD-TRK)
DS1 Central Office Trunks (CO-DS1)
DS1 Direct Inward Dialing Trunks (DID-DS1)
DS1 Tie Trunks (TIE-DS1)
ISDN Trunks (ISDN-TRK)
Tie Trunks (TIE-TRK)