DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-1006SYNC (Synchronization)
3
Notes:
a. This error indicates a problem with the primary DS1 reference. It is cleared
when the primary reference is restored. The following steps should give an
indication of the source of the problem:
1. Check if the primary DS1 interface circuit pack is inserted in the
carrier via the
list configuration board PCSS
command.
2. Check the connection of the cable supplying the external timing
source to the primary DS1 interface circuit pack.
3. Test the primary DS1 interface circuit pack via the
test board PCSS
long
command. Check the Error Log for DS1-BD errors and refer to
the DS1-BD (DS1 Interface Circuit Pack) Maintenance
documentation to resolve any errors associated with the primary
DS1 interface circuit pack. If no errors are listed in the Error Log for
the primary DS1 interface circuit pack, continue with the following
steps.
4. Test the active Tone-Clock circuit pack in the master port network
via the
test tone/clock PC long
command. Check the Error Log for
TDM-CLK errors and verify that TDM Bus Clock Test #148 passes
successfully. If Test #148 fails with an Error Code 2 through 32, refer
to ‘‘TDM-CLK (TDM Bus Clock)’’
to resolve the problem. If not,
continue with the following steps.
769 (e) None MAJOR/
WARNING
3
OFF None
1793
4
0-50 None MAJOR/
WARNING
OFF enable sync
2049 (f) (h)
4
0 None WARNING OFF None
2305 (g) (h)
4
0 None WARNING OFF None
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
2. This error type initially raises a Warning alarm. If this error type persists and alarms are not
downgraded on this MO due to the value of set options, then, after a period of time, a Minor or Major
alarm is raised.
3. Major alarms on this MO may be downgraded to Warning alarms based on the value used in the set
options command.
4. It may take up to one hour for these SYNC alarms to clear due to "leaky bucket" strategy.
Table 3-446. Synchronization Error Log Entries — Continued
Error Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
Continued on next page