DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-351CLAN-BD (Control LAN Circuit Pack)
3
3. If circuit pack resets, execute Packet Interface Test (#598) several
times.
4. If Packet Interface Test (#598) continues to fail, replace the circuit
pack.
l.
Error Type 2305-2306
: Error in received frame from packet bus.
Most likely cause—packet bus problem.
Other cause—circuit pack fault.
Invalid LAPD frame errors occur when the frame
contains a bad Cyclic Redundancy Check (CRC),
is greater than the maximum length,
violates the link level protocol.
1. Retry the command (
test board UUCSS
) and see if the condition
clears.
2. If condition persists, execute PPE/LANBIC Receive Parity Error
Counter Test (# 597) and determine if the condition clears.
3. If condition persists, execute Packet Interface Test (# 598) to verify
circuit pack integrity.
4. If Packet Interface Test (# 598) fails, consult repair procedure for
the packet bus.
m.
Error Type 2561-2668:
System software received an indication that the
socket was closed due to an error. Errors are reported as log only. Errors
logged here are for the sockets that had
no
processor channels
associated with them, for example, sockets to read SNMP data. The
counter base is offset by the application type of the application associated
with this socket that is down. The Aux Data field of the log entry contains
this application’s number, for example, a SNMP application would have its
application number in the Aux Data field.
NOTE:
2561 - 2668 is a range of reserved numbers for future applications.
2570 currently represents an SNMP socket failure.
n.
Error Type 2817-2819
: Congestion Query Test (#600) failed.
Error Type: Description
2305 Received invalid LAPD frame.
2306 Detected parity error on received frame.