DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-54ANL-LINE (8-Port Analog Line), ANL-NE-L (8-Port Neon Analog Line)
3
40975indicates that the terminal equipment was on-hook when
ring-tip was detected during ringing. This usually indicates a failure
in the terminal equipment or the type of terminal has a low ringer
impedance. Call the terminal equipment and verify that the terminal
rings. If the terminal doesn’t ring, then replace it. Otherwise, issue
the
test port PCSSpp
command, and follow the procedure for Test
#48.
40977indicates that no terminal equipment was connected when
ringing was attempted. Run the Short Test via the
test port
PCSSpp
command, and follow the procedure for the results of Test
#48.
b. This is a software audit error that does not indicate any hardware
malfunction. Run Short Test Sequence and investigate errors (if any).
c. This error type indicates that the circuit pack has been removed or has
been insane for more than 11 minutes. To clear the error, reinsert or
replace the circuit pack.
d. Test #48 may cause some terminal equipment to ring briefly during daily
maintenance. If this ringing is disturbing the customer or the terminal
equipment, it should be disabled via the
change station <extension>
command. However, on some releases of the software, this disables Tests
#6, #47, and #35 as well as Test #48.
e. Test #47 may cause a false alarm when the port is connected to
off-premises equipment, some non-voice terminal equipment, and some
loop equipment. If this causes a false alarm, then disable the test by
changing the Tests field of the
change station
command to "no."
f. Refer to "XXX-BD (Common Port Circuit Pack)" Maintenance
documentation.
System Technician-Demanded Tests: Descriptions
and Error Codes
Always investigate tests in the order presented in the table below when
inspecting errors in the system. By clearing error codes associated with the
Battery Feed Test
, for example, you may also clear errors generated from other
tests in the testing sequence.