Lucent Technologies 555-233-119 Home Theater Server User Manual


  Open as PDF
of 1872
 
DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-363test pms-link
2
Feature Interactions
The maintenance of a particular component on a link may interfere with the
maintenance of the link itself. Maintenance can put a link component in a busy
state causing link set-up to fail. Frequent attempts at re-setup of a link may delay
the recovery of a faulty component due to the maintenance test of a component
only taking place when the component is idle. Therefore, the technician needs to
be able to disable the attempted re-setup of a link. The
busyout
command is
used to do this and causes the link to be torn down. If the link is already down,
the
busyout
command stops periodic re-setup tries on the link.
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
test pms-link
short
long
repeat
number
clear
schedule
Option for a brief series of
nondestructive diagnostic tests.
Option for a longer, more
comprehensive series of both
destructive and nondestructive
diagnostic tests.
How many times each test in the
sequence is repeated (1-100)
This option causes the test
sequence (short or long) to repeat
until the alarm (if any) is cleared or
a single test in the sequence fails.
1
Command is validated and then a
scheduling form displays to
schedule execution of the
command. The command is then
placed in the command queue and
is executed at the specified time.
The information displayed by the
command is sent to the system
printer instead of the screen.
2
Examples:
test pms-link sh r 5
test pms-link l
test pms-link
test pms-link c
test pms-link c sch
1 If no alarms are registered against the maintenance object then the test sequence is run only once. The
long clear
option forces a clear of all alarms if no errors are encountered during testing. The
short clear
option only clears
alarms pertinent to tests in the short sequence.
2 Refer to the Report Scheduler and System Printer feature specification for more details.
init
inads
craft
Test
Sequence
= short;
Repeat =
1
See below