DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-702HYB-LINE (Hybrid Line)
3
Table 3-296. TEST #61 Hybrid Line Audits Test
Error
Code
Te s t
Result Description/ Recommendation
ABORT Internal System Error
1 ABORT The test was aborted due to an internal system error during the switchhook
audit.
2 ABORT Internal System Error occurred during bad scan inquiry audit.
1. Make sure that the station is not in an out of service state.
2. Retry the command at 1-minute intervals a maximum of 5 times.
3 ABORT This port may have been busied out by system technician.
1. Look in the Error Log for Error Type 18 (port busied out) for this port. If
this error type is present, the release the port via the release station
<extension>
command and run the test again.
2. Make sure that the terminal is connected.
3. Retry the command at 1-minute intervals a maximum of 5 times.
1000 ABORT System resources required to run this test are not available. The port may
be busy with a valid call. Use the display port PCSSpp to determine the
station extension number of the port. Use the status station command to
determine the service state of the port. If the service state indicates that
the port is in use, then the port is unavailable for certain tests. You must
wait until the port is idle before retesting. Attendants are always in use
(off-hook), if the handset is plugged in and the port is not busied out.
1. If the port status is idle, then retry the command at 1-minute intervals a
maximum of 5 times.
1004 ABORT The port was seized by a valid call during the test. The test has been
aborted. Use the display port PCSSpp command to determine the station
extension number of the port. Use the status station command to
determine the service state of the port. If the service state indicates that
the port is in use, then the port is unavailable for certain tests. You must
wait until the port is idle before retesting. Attendants are always in use
(off-hook), if the handset is plugged in and the port is not busied out.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2000 ABORT Response to the test request was not received within the allowable time
period.
FAIL Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
Continued on next page