Lucent Technologies 555-233-119 Home Theater Server User Manual


  Open as PDF
of 1872
 
DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-45display alarms
2
Output
After you complete the options screen, the system displays a 1- or 2-page Alarm
Report. To toggle between the pages and to exit the report, use the keys
described below:
For 513 and 715 terminals, use
F8
for NEXT PAGE and PREV PAGE commands
For all other terminals, use
F7
for NEXT PAGE and PREV PAGE commands
Use
Esc
for the CANCEL command.
The screen below shows an example of an Alarm Report.
Category
Object code for the equipment category. Press
HELP in this field to
view a list of the object codes.
Extension
Extension number (per dial-plan)
Trunk
Enter a group number or a group and member number:
Enter
only
the
group
number (01-99) to display
all
members in
the group. Example: 01/__
Enter
both
the
group
number
(01-99)
and
member
number
(01-99) to display a
specific
member in a group.Example: 01/99
display alarms
ALARM REPORT
Port Maintenance On Alt Alarm Svc Ack? Date Date
Name Brd? Name Type State 1 2 Alarmed Resolved
01C07 ANL-BD y MINOR n n 05/22/20:26 00/00/00:00
01C0702 ANL-LINE n 311 WARNING IN 05/22/20:26 00/00/00:00
01C0701 ANL-LINE n 1051 WARNING IN 05/22/20:26 00/00/00:00
01C0703 ANL-LINE n 1053 WARNING IN 05/22/20:26 00/00/00:00
01C1505 CO-TRK n 78/01 WARNING OUT 05/22/20:26 00/00/00:00
01C1505 CO-TRK n 78/01 WARNING OUT 05/22/20:26 00/00/00:00
PN 02B TDM-BUS n WARNING 05/23/14:53 00/00/00:00
Command successfully completed