Lucent Technologies 555-233-119 Home Theater Server User Manual


  Open as PDF
of 1872
 
DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-953PR-MAINT (Maintenance Processor)
3
MTP Auxiliary Loop Around Test (#229)
This test is a nondestructive test. The test places the Auxiliary channel of the MTP
into a loop around mode, and it verifies the data integrity of the channel. The
Auxiliary channel is used as the CDR output port.
Table 3-413. TEST #229 MTP Auxiliary Loop Around Test
Error
Code
Tes t
Result Description/ Recommendation
1029
2014
2015
2016
2017
2018
2020
2022
2024
2025
2051
ABORT Refer to STBY-SPE Maintenance documentation for a description of these
error codes.
1000 ABORT The system software resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1018 ABORT The test has been disabled via administration. The change
system-parameters cdr command needs to administer CDR.
2000 ABORT Response to the test request was not received within the allowable time
period.
2033
2034
ABORT Internal system error
Port busy
Retry the command at 1-minute intervals a maximum of 5 times.
22902
22903
ABORT The system software resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
FAIL The Auxiliary channel failed the Loop Back Test. The AUX port is probably not
sending any auxiliary data to the auxiliary collection device.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If test continues to fail, replace the Processor circuit pack.
PASS The Auxiliary channel passed the Loop Back Test. The auxiliary port is
functioning correctly.
1. If no auxiliary data is being recorded, check the auxiliary collection
device, and verify that it has been set up and connected correctly.
Continued on next page