DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-526DIOD-DS1 (DS1 DIOD Trunk)
3
c. Error Type 18
System Technician has busied out the trunk to the
out-of-service state. No calls can be made on this trunk except the Facility
Access Test Call. For details on this feature, refer to "Facility Test Calls"
section in Chapter 5, "Routine Maintenance Procedures".
d. Error Type 130
This error type indicates that the circuit pack has been
removed or has been insane for more than 11 minutes. To clear the error,
reinsert or replace the circuit pack.
e. Error Type 257
The DS1 Interface circuit pack detects a hardware fault.
Aux Data 57392 indicates no external release on PBX disconnect.
f. Error Type 513
The DS1 Interface circuit pack detects a hardware fault.
Aux Data 57393 indicates belated external release on PBX disconnect.
g. Error Type 769
The DS1 Interface circuit pack detects a hardware fault.
The Aux Data field contains the following error type:
57484, fault is
detected on tip/ring.
h. The DS1Interface circuit pack detects a hardware fault, and the Aux Data
field contains the following error type: 51200, port is unavailable. Run the
Dial Tone Test (#314) and follow procedures.
i. Error Type 1793
DS1 Interface circuit pack is out-of-service. Look for
UDS1-BD errors in the Hardware Error Log if the port is on a TN464 UDS1
board. Refer to the UDS1-BD (DS1 Trunk Circuit Pack) Maintenance
documentation for details
j. Error Type 2049
—With the following Aux Data:
Aux Data 57473—Rotary dial rate below 8 pulses per second.
Aux Data 57474—Rotary dial rate above 12 pulses per second.
Aux Data 57475
Rotary Dial interdigit time is too short.
The DS1 interface circuit pack detects a hardware error on the DS1 DIOD
trunk. The trunk can not communicate with the far-end because it is unable
to interpret digits sent from the far-end switch. Check with the far-end
switch or Operating Company for proper trunk connection.
k. Error Type 2305
—Recorder message, trunk could not be seized (Aux Data
50944). Run Test #314 and follow the outlined procedures.
l. Error Type 2562
Retry Failure error. This error is logged only. It is not a
hardware failure and hence does not start any testing or generate any
alarms. This error comes from call processing and is generated when a
second attempt (retry) to seize an outgoing trunk fails.
m. Error Type 2817
Glare error. This error is logged only. It is not a hardware
failure and hence does not start any testing or generate any alarms. This
error is the result of a simultaneous seizure of a two-way trunk from both
the near-end and the far-end. Attempt to place the call again. If the error
persists, execute the Dial Tone Seizure Test (#314) and follow those
procedures.