DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-523DIOD-DS1 (DS1 DIOD Trunk)
3
DIOD-DS1 (DS1 DIOD Trunk)
NOTE:
Many trunk problems are caused by incorrect settings of parameters on the
trunk group administration form. Settings must be compatible with the local
environment and with parameter settings on the far-end. Refer to
DEFINITY
Enterprise Communications Server Administrator’s Guide
for information on
how to administer trunks. The Application Notes section of that book shows
the correct settings for administrable timers and other parameters on a
country-by-country basis.
A DS1 DIOD trunk provides a link for digitized voice or data communications
between the system and a central office switch. There are two types of DS1
interfaces:
24 DS0 channels on a 1.544 Mbps link
31 DS0 channels + 1 framing channel on a 2.048 Mbps link
32-channel mode is supported only on TN464 circuit packs and on G3r V2
systems.
The DS1-DIOD maintenance object monitors and maintains a DIOD trunk port on
a TN464 UDS1 Interface circuit pack. See UDS1-BD in this chapter for more
information about this circuit pack. The DS1 circuit pack supports low level CO
trunk signaling interfaces for both ground-start and loop-start trunks. This
maintenance strategy covers the in-line errors log, initialization tests, periodic
tests, scheduled tests, demand tests, and alarm resolution and escalation.
MO Name (in
Alarm Log)
Alarm
Level Initial Command to Run Full Name of MO
DIOD-DS1 MAJOR
1
1. A Major alarm on a trunk indicates that alarms on these trunks are not downgraded
by the set options command and that at least 75 percent of the trunks in this trunk
group are alarmed.
test trunk
group# member#
l DS1 DIOD Trunk
DIOD-DS1 MINOR test trunk
group# member#
l DS1 DIOD Trunk
DIOD-DS1 WARNING test trunk
group# member#
DS1 DIOD Trunk