Lucent Technologies 555-233-119 Home Theater Server User Manual


  Open as PDF
of 1872
 
DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-8busyout journal-printer
2
Feature Interactions
Maintenance of a particular component on a link sometimes interferes with the
maintenance of the link itself. For example, maintenance can put a link
component in a busy state causing link set-up to fail. Frequent attempts at
re-setup of a link may delay the recovery of a faulty component, due to the
maintenance test of a component only taking place when the component is idle.
Therefore, disable the attempted re-setup of a link with the busyout command
and the link will remain intact. If the link is already down, the busyout command
stops periodic re-setup attempts on the link.
Output
The following example shows the output for the
busyout journal-printer
wakeup-log
command.
Field descriptions
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
busyout
journal-printer
pms-log
wakeup-
log
Link to pms (in output, port name for
pms link =1)
Link to the wakeup logging facility (in
output, port name = 0)
Examples:
busyout journal-printer pms-log
busyout journal-printer wakeup-log
init
inads
craft
nms
None See below
Port
Physical object port address:
0
= wakeup log,
1
= pms log
Maintenance Name
The name of the maintenance object
Alt. Name
Not applicable
Result
Test result: Pass, Abort, Fail
Error Code
Numeric code explaining why the release failed or aborted. Refer
to the detailed list of the codes by test number for each MO.
busyout journal-printer wakeup-log SPE A
COMMAND RESULTS
Port Maintenance Name Alt. Name Result Error Code
0 JRNL-LINK PASS
Command successfully completed