DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-329test cdr-link
2
Output
The following example shows the output for the
test cdr-link primary
command.
The responses display on a test-by-test basis with one line of data for each test
result.
Field descriptions
Port
Not applicable (always blank)
Maintenance
Name
The type of MO being tested: primary cdr-link= PRI-CDR; secondary
cdr-link = SEC-CDR
Alt. Name
Not applicable (always blank)
Test No
The test being executed
Result
Test result: Pass, Abort, Fail, Disabled
Error Code
Numeric code explaining why the release failed or aborted. Refer to the
detailed list of the codes by test number for each MO.
test cdr-link primary short
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
PRI-CDR 215 PASS
Command Successfully Completed